Clip the meter probes to the plug's outer prongs.

Clip jumper wire across the outer cord terminals.

Bend and pull the cord. Replace the cord if the multimeter reads above zero ohms or fluctuates.

Clip the jumper across the middle and one outer terminal, then clip the multimeter to the corresponding plug prongs. Look for steady zero-ohms readings. If readings fluctuate, replace the cord and/or plug.